SDM-2020 Satellite Demodulator

Revision 4

Remote Control Commands

MN/SDM2020D.IOM

A–20

Current
Sweep
Value

Command:
Response:

>add/CSV_xsnnnnn'cr'
CD_yyy'cr''lf']

Where:

x = < or > (data modifier to indicate that the sweep
offset value is less than or greater than the returned
value).

s = + or - (sweep offset from center).

nnnnnn = 0 to 500000.

yyy = OK or FLT (decoder lock status OK or FAULT).


This command returns the current sweep offset value.

Notes:

1. The 'x' (< or >) parameter is only returned if the

level has exceeded the computational resolution of
the system.

2. 'No Data' is returned if the level cannot be

calculated.

3. 'Sampling' is returned if not enough data is

currently available to calculate the level.

LNB
Current
Monitor
Status

Command:
Response:

>add/CMS_nnnn'cr''lf']

Where: nnnn = 0 to 1000 mA in 1 mA steps.

A.1.13 Stored

Faults

Information on stored faults is returned when requested. If no stored fault exists for a
given fault number, the words “No Fault” will be returned, instead of the normal
time/date status information.

The following symbols are commonly used to define the stored faults status commands:

• #

Fault number (0 to 9). “0” is the first fault stored.

• hh

Hours in 24-hr. format.

• mm Minutes.
• ss

Seconds.

• MM Month.
• DD Day.
• YY Year.

Demodulator
Stored Faults

Command:
Response:

>add/DSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
BERT_xxx'cr'
EBNT_xxx’cr’
CONF_xxx'cr''lf']



Demodulator Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
BER Threshold (OK/FLT)
E

b

/N

0

Threshold (OK/FLT)

Configuration (OK/FLT)