beautypg.com

Fault connector (j2), 2 fault connector (j2) – Comtech EF Data SDM-2020 User Manual

Page 45

background image

SDM-2020 Satellite Demodulator

Revision 4

Installation

MN/SDM2020D.IOM

3–5

3.2.2

Fault Connector (J2)

The fault interface connection is a 9-pin female D connector located on the rear panel of the
demodulator. Screw locks are provided for mechanical security on the mating connector.

The fault connector provides FORM-C contact closures for fault reporting. The two
FORM-C summary fault contacts are Demodulator and Common Equipment. To obtain a
system summary fault, connect all of the FORM-C contacts in parallel.

Table 3-3 provides the pinout of the J2 connector.

Table 3-3. Faults Status Relays Connector Pinout (J2)

Pins Connected

Signal Function

Name

Pin #

Type

Fault/

Alarm

OK

Power

OFF

Common Equipment Fault

CE_NO
CE_COM
CE_NC

1
2
3

FC
FC
FC

2-3

1-2

2-3

Demodulator Fault

DEM_NO
DEM_COM
DEM_NC

4
5
6

FC
FC
FC

5-6

4-5

5-6

Demodulator Alarm

ALM_NO
ALM _COM
ALM _NC

7
8
9

FC
FC
FC

7-8

8-9

8-9

Note: A connection between the common (COM) and normally open (NO) contacts indicates no