beautypg.com

9 environmental requirements – Comtech EF Data SDM-2020 User Manual

Page 181

background image

SDM-2020 Satellite Demodulator

Revision 4

G.703 Data Interface

MN/SDM2020D.IOM

11–15

Table 11-11. G.703 Auxiliary Connector Pinout

Auxiliary Connector Pinout

Signal Function

Name

Pin #

Type

Comment

1

GND

Signal

Ground

Demod Fault
Indicator

DF

2

O

Demodulator Summary Fault
Redundancy switch application,
TTL open collector output

Not Used

N/A

3, 5, 8, 9

N/A

Wire to spare pad

Carrier Detect

CD

7

O

Demodulator, TTL output

11.1.9

Environmental Requirements

Temperature Range:
Operational
Storage


0 to 50

°C (32 to 122°F)

-40 to 70

°C (-40 to 158°F)

Humidity

0 to 95% Non-Condensing

Operational Shock

MIL-STD-167-1

Survivability Shock/Vibration MIL-STD-810D Method 514.4, Procedure 8, 1 hour per

axis

11.1.10

G.703 Interface Front Panel Menus

The applicable menus are dependent on the G.703 interface application.

11.1.11 G.703

Remote Interface Commands

The applicable remote commands are dependent on the G.703 interface application.