Revision 4
Front Panel Operation
MN/SDM2020D.IOM
6–48
The current baud rate and parity selection of the demodulator are displayed.
To set the demodulator baud rate and/or parity,
1. Press
2. Press
[
←] or [→] to position the flashing cursor over the parameter to be
changed.
3. Press
[
↑] or [↓] to change the parameter to the desired value.
4. Once the parameters are displayed as desired, press
to set the baud
rate and parity. The baud rate can be set at 300, 600, 1200, 2400, 4800, 9600, or
19200. The parity can be set to EVEN, ODD, or NONE.
Upon entry, the current status is displayed. Press [
↑] or [↓] to change the selection. Press
Function Select: Utility: System: Remote Address
REMOTE ADDRESS
1
Displays the CURRENT ADDRESS. Address may be between 1 to 255.
Note: Address 0 is reserved as a global address
Upon entry, the current status is displayed. Press [
↑] or [↓] to change the selection. Press
Function Select: Utility: System: Remote Type
REMOTE TYPE
RS-485 (4-WIRE)