SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Ethernet-based Remote Product Management
Revision 1
4–22
4.5.4.3.3
Config | Redundancy
Appendix A. 1:1 REDUNDANCY
Use this page to configure the SPOD’s Redundancy Switch Mode.
Figure 4-8. Config | Redundancy Page
Click [Refresh] (at the top of the page) to update the page appearance to the current operating
configuration.
Redundancy
To update the page to the current redundancy configuration: Click [Refresh].
Enable Redundancy Switch Mode
Use the drop-down list to select the Switch Mode as follows:
• Off – Disables redundancy.
• 1:1 Red TX – Enables 1:1 redundancy with transmit switch control.
• Manual: Enables manual redundancy mode.
The 1:1 Red TX+RX selection is non-functional on the SPOD Web Server Interface.
Click [Change] once the desired mode selection has been made.
Online Status
This read-only section displays the active status for the unit as either Online or Offline.
Force Online
To force a unit to go active (online): Click [Force Online].