beautypg.com

Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 128

background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Appendix A

Revision 1

A–2

Figure A-1. Ethernet-based M&C using CEFD Kit KT-0000203

A.3.1.1

1:1 Redundant System Setup (Using a Single Ethernet Interface)

See Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT for detailed

information about the remote commands and queries specified in this section.

To set up a 1:1 Redundancy System using a single Ethernet interface, do these steps:

Step

Task

1

Turn both units off, and then connect them to the redundant system hardware using the proper cables.

2

Turn on Unit #2, and change its serial remote address from 1 (factory default) to a valid unique value

(typically 2) so that it does not conflict with any other unit in the system.

3

Change Unit #2’s IP address from the factory default (192.168.1.4/24) to a valid unique value (typically

192.168.1.3/24) so that it does not conflict with any other unit in the system.

4

Enable redundant mode by setting the ESW serial remote command (ESW=1). The waveguide switch /

switches throw may be heard when redundant mode is enabled. Unit #2 is now the online unit.

5

Turn on Unit #1.

6

Change Unit #1’s serial remote address / IP address if necessary (typically the factory default values are

correct).

7

Enable redundant mode by setting the ESW command (ESW=1). The waveguide switch / switches throw

may be heard when redundant mode is enabled. Unit #1 is now the online unit.

8

Set up all parameters for Unit #1 so that the configuration can be copied to Unit #2 (AMP, MUT, ATT, etc.).