SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Serial-based Remote Product Management

Revision 1

5–21

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Unit Alarm Mask

MSK=

5 bytes

Command or Query.

Sets or returns alarm mask conditions in the form abcde, where:

0 = Fault, 1 = Alarm, 2 = Masked

a = Low Forward RF Power

b = External Reference Lock detect

c = Fan Speed

d = LNB Current Detect

e = LNB 22V Power Supply

Default value: 22111

Example: <1/MSK=22111’cr’

>0001/MSK=1’cr’’lf’

MSK=

MSK?

MSK*

MSK?

MSK=abcde

(See Description of

Arguments)

Mute State

MUT=

1 byte

Command or Query.

Sets or return the unit mute state in the form x, where:

0 = Disable (Not Muted)

1 = Enable (Muted) (default value)

2 = Unit muted due to AUX mute signal (see Note)

Note: This value is only shown in the response to a query, and cannot be given as a command. When MUT

returns a ‘2’ it indicates that one of the “hardware” mute conditions is present. For example, an auxiliary mute

could be present if the auxiliary mute has been enabled, and the signal to unmute the unit is not provided. If

MUT returns an unexpected value of ‘2’ then check the active faults and the status of the auxiliary mute.

Example: <1/MUT=1’cr’

>0001/MUT=1’cr’’lf’

MUT=

MUT?

MUT*

MUT?

MUT=x

(See Description of

Arguments)

Number of Unread

Stored Events

N/A

3 bytes

Query only.

Returns the number, in the form xxx, of unread stored events

Example: <1/NUE?’cr’

>0001/NUE=126’cr’’lf’

NUE=

NUE?

NUE=xxx

Number of Unread

Stored Statistics

N/A

3 bytes

Query only.

Returns the number, in the form xxx, of unread stored statistics

Example: NUS=126

NUS=

NUS?

NUS=xxx