Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 125
![background image](https://www.manualsdir.com/files/778855/content/doc125.png)
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Serial-based Remote Product Management
Revision 1
5–33
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
External
Reference Mute
O
XRM=
1 byte
numeric
Command or Query.
Sets or returns the external reference mute state in the form x, where:
0 = Disable
1 = Enable (see Note)
Note: To enable this command, the internal reference oscillator option must be installed; otherwise, a mode
error will result. A hardware mute condition generated by the XRM mute is one of the conditions that can cause
the MUT command to return MUT=2.
When enabled, the unit will mute if an external reference oscillator is not detected.
Example: <1/XRM=1’cr’
XRM=
XRM?
MSK*
XRM?
XRM=x
(See Description of
Arguments)