SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Appendix A

Revision 1

A–3

A.3.2

Serial-based Monitor and Control

The EIA-232 Interface is not available for 1:1 Redundancy.

See Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT for detailed

information about the remote commands and queries specified in this section.

Serial-based Remote Product Management/Monitor and Control (M&C) of any SPOD Standalone

or 1:1 Redundancy application is available through use of the optional CLC-10 Handheld

Terminal M&C Accessory Kit (CEFD Kit KT-0020518). This kit provides the user with on-site

access to the SPOD’s serial remote control interface. For detailed information about this

optional accessory, see the CLC-10 Comtech LPOD Controller User’s Guide (CEFD P/N

MN-CLC10).

Figure A-2. Serial-based M&C using CEFD Kit KT-0020518

Serial command ESW determines system operation. If ESW=1 is executed in both units, the

system will be in Automatic Redundancy mode. In this mode, if a fault is detected with the

active (online) unit – either by loss of communications between the backup (offline) and active

units, or via the summary fault – the backup unit will trigger the waveguide switch and,

assuming the backup unit is not faulted, will become the active unit. The backup unit will also

poll the active unit at regular intervals in an attempt to maintain configuration compatibility

with the active unit; this ensures that, should a fault occur, the backup unit is configured exactly

the same as the active unit.