3 connector ‘j3 | power in’ (ac power mains), 2 spod ps 2 ‘j3 | power in’ (ac power main) – Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 39
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
System Connections, Installation and Startup
Revision 1
2–5
2.3.3
Connector ‘J3 | POWER IN’ (AC Power Mains)
WARNING! FOR SAFETY REASONS, TAKE CARE TO NOTE THAT THE ‘J3’ AC POWER
CONNECTION PIN ASSIGNMENTS FOR EACH SPOD UNIT ARE NOT THE SAME.
FAILURE TO CAREFULLY REVIEW THE INFORMATION PROVIDED IN THE SECTIONS
THAT FOLLOW MAY RESULT IN PRODUCT DAMAGE OR PERSONAL INJURY.
For all SPOD units, the prime power input requirement is as follows:
• 90-264 VAC
• 47 to 63 Hz
• The power supply is power factor corrected. The total power required from the prime power
supply depends on the unit used. See Sect. 1.4 Summary of Specifications.
2.3.3.1
SPOD PS 1, PS 1.5 ‘J3 | POWER IN’ (AC Power Main)
The mating connector specification and pin assignments (Table 2-2) unique to the
SPOD PS 1 and PS 1.5 AC power interfaces are as follows:
Mating Connector: CEFD P/N CN/MS-STPG03F02 (ITT Cannon KPT06B-12-35).
Table 2-2. SPOD PS 1/PS 1.5 ‘J3 | POWER IN’ Pin Assignments
Pin
Description
A
LINE (L1)
B
NEUTRAL (L2)
C
GND
2.3.3.2
SPOD PS 2 ‘J3 | POWER IN’ (AC Power Main)
The mating connector specification and the pin assignments (Table 2-3) unique
to the SPOD PS 2 AC power interface are as follows:
Mating Connector: CEFD P/N CN/MS-STPG03F07 (Glenair ITS-3106F20-19SF7).
Table 2-3. SPOD PS 2 ‘J3 | POWER IN’ Pin Assignments
Pin
Description
A
GND
B
NEUTRAL (L2)
C