SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Preface

Revision 1

xiii

Electrical Safety Notice

CAUTION – Neutral Fusing: Double pole/neutral fusing is used on the prime power

supply input.

This equipment is designed to minimize exposure of personnel to hazards. For further

information, contact Comtech EF Data Product Support. The operators and technicians must:

• Know how to work around, with, and on high voltage equipment.

• Exercise every precaution to ensure personnel safety.

• Exercise extreme care when working near high voltages.

• Be familiar with the warnings presented in this manual.

Installation Guidelines Regarding Power Line Quality

Comtech EF Data has become familiar with the varying quality of the AC power grid

around the world. Observing the following installation guidelines should help ensure

a reliable installation.

Surge suppression: High voltage surges can cause failure of the power supply. These surges

are typically caused by circuit switching on the main AC power grid, erratic generator

operation, as well as lightning strikes. While the SPOD does have built in surge suppression,

if unit installation occurs in a location where there may be questionable power grid quality,

Comtech EF Data recommends installation of additional power conditioning/surge

suppression at the power junction box.

Grounding: The SPOD provides a grounding terminal. This is provided to allow grounding of

the SPOD to the antenna’s grounding network. All installed components should be grounded

to a common grounding point at the antenna.

Electrical welding: If welding needs to take place at the antenna, disconnect all cables from

the SPOD except for the ground wire. Cap all RF connections with terminations. This will

prevent damage to the input/output circuitry of the SPOD.

Lightning: Lightning strikes on or around the antenna will generate extremely high voltages

on all cables connected to the SPOD. Depending on the severity of the strike, the SPOD’s

internal surge protection combined with the recommended external suppression may

protect the SPOD’s power supply. However, if the installation will be in an area with a high

probability of lightning strikes, Comtech EF Data recommends the installation of surge

suppression on the RF and IF cables. One source of these suppressors is PolyPhaser

(www.polyphaser.com).