Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 111
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Serial-based Remote Product Management
Revision 1
5–19
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
Local/Remote
State
LRS=
1 byte
Command or Query.
Sets or returns Local or Remote state for Indoor SSPA (always in remote mode for Outdoor SSPA) in the form x,
where x=0, 1, 2, or 3::
0 = Local
1=Serial
2=Ethernet
3=Serial+Ethernet (default value)
Note: The user will always have query access in any mode. The LRS command is also available in all modes as
a means of acquiring control. The intent of this command is to limit changes from being made on multiple
interfaces at the same time. Units without a front panel will treat an entry of 0 as reserved, and will refuse the
command by returning a mode error. The web page GUI will refuse connections unless LRS is set to enable
Ethernet remote control.
Example: <1/LRS=3’cr’
>0001/LRS=’cr’’lf’
LRS=
LRS?
LRS?
LRS=x
(See Description of
Arguments)
Unit MAC Address N/A
17 bytes
Query only.
Returns the MAC address of the unit, in hexadecimal format xx-xx-xx-xx-xx-xx
Example: <1/MAC?’cr’
>0001/MAC=00-06-B0-00-D2-A7’cr’’lf’
MAC=
N/A
MAC=xx-xx-xx-xx-
xx-xx
(See Description of
Arguments)