Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 112

background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Serial-based Remote Product Management

Revision 1

5–20

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Maximum

Operating point

N/A

272 bytes

Query only.

Returns the maximum operating point of the unit along with its timestamp

Reply format:

MAXFET=sYYYC mmddyy hhmmss’cr’

MINFET=sYYYC mmddyy hhmmss’cr’

MAXPFT=sYYYC mmddyy hhmmss’cr’

MAXDTP=sYYYC mmddyy hhmmss’cr’

MAXHTS=sYYYC mmddyy hhmmss’cr’

MINHTS=sYYYC mmddyy hhmmss’cr’

MAXOST=sYYYC mmddyy hhmmss’cr’

MAXRFP=sZZ.ZZ mmddyy hhmmss’cr’

MINRFP=sZZ.ZZ mmddyy hhmmss’cr’

Where:

sYYYC is the temperature

sZZ.ZZ is the power

Note: not all SPODs have outside temperature monitor. In that case, MAXOST and MINOST will report XXXXX

XXXXXX XXXXXX

Example: <1/MOP?’cr’

>0001/mop=’cr’

MAXFET=+000C 010208 180729’cr’

MINFET=+000C 010208 180729’cr’

MAXPFT=+000C 010208 180659’cr’

MAXDTP=+000C 010208 180729’cr’

MAXHTS=+050C 010208 180729’cr’

MINHTS=+050C 010208 180729’cr’

MAXOST=XXXXX XXXXXX XXXXXX’cr’

MINOST=XXXXX XXXXXX XXXXXX’cr’

MAXRFP=+00.00 010208 180659’cr’

MINRFP=+00.00 010208 180659’cr’

MOP=

N/A

(See Description of

Arguments)