Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 112
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Serial-based Remote Product Management
Revision 1
5–20
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
Maximum
Operating point
N/A
272 bytes
Query only.
Returns the maximum operating point of the unit along with its timestamp
Reply format:
MAXFET=sYYYC mmddyy hhmmss’cr’
MINFET=sYYYC mmddyy hhmmss’cr’
MAXPFT=sYYYC mmddyy hhmmss’cr’
MAXDTP=sYYYC mmddyy hhmmss’cr’
MAXHTS=sYYYC mmddyy hhmmss’cr’
MINHTS=sYYYC mmddyy hhmmss’cr’
MAXOST=sYYYC mmddyy hhmmss’cr’
MAXRFP=sZZ.ZZ mmddyy hhmmss’cr’
MINRFP=sZZ.ZZ mmddyy hhmmss’cr’
Where:
sYYYC is the temperature
sZZ.ZZ is the power
Note: not all SPODs have outside temperature monitor. In that case, MAXOST and MINOST will report XXXXX
XXXXXX XXXXXX
Example: <1/MOP?’cr’
>0001/mop=’cr’
MAXFET=+000C 010208 180729’cr’
MINFET=+000C 010208 180729’cr’
MAXPFT=+000C 010208 180659’cr’
MAXDTP=+000C 010208 180729’cr’
MAXHTS=+050C 010208 180729’cr’
MINHTS=+050C 010208 180729’cr’
MAXOST=XXXXX XXXXXX XXXXXX’cr’
MINOST=XXXXX XXXXXX XXXXXX’cr’
MAXRFP=+00.00 010208 180659’cr’
MINRFP=+00.00 010208 180659’cr’
MOP=
N/A
(See Description of
Arguments)