SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Serial-based Remote Product Management

Revision 1

5–14

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Concise

Maintenance

Status

N/A

95 bytes

Query only.

This is the concise version of the RMS command. Returns the Maintenance status of the unit, response is

semicolon delimited, in the form aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;

ooo.o;ppp.p;qqq.q;rrr.r;sss.s;ttt.t where:

aaa.a = P24V1

bbb.b = P24V2

ccc.c = LNBVT (Not applicable on the SPOD)

ddd.d = P13VT

eee.e=P10V1

fff.f = A10V1

ggg.g = A10V2 (see Note)

hhh.h = P7V8T

iii.i = P5V8T

jjj.j = P2V5T

kkk.k = P1V2T

lll.l = N5V8T

mmm.m = FANR1 (see Note)

nnn.n = FANR2 (see Note)

ooo.o = BUCVT (Not applicable on the SPOD)

ppp.p = FWPWR

qqq.q = REFVT (Not applicable on the SPOD)

rrr.r = LNBCS (Not applicable on the SPOD)

sss.s = ATEMP

ttt.t = OTEMP (see Note)

Note: ggg.g, mmm.m, nnn.n, and ttt.t will appear if the appropriate model/options have been selected/installed.

Otherwise, the unused fields will display XXXXX.

CMS=

CMS?

CMS=x….x

(See Description of

Arguments)

Concise Utility

Status

E

N/A

15 bytes

Query only.

Returns the Maintenance status of the unit, response is semicolon delimited, in the form aaaa;bbbbb;ccc where:

aaaa = Remote Unit Address

bbbbb = Remote Baud Rate

ccc = Reference oscillator tuning voltage DAC value (see Note)

Note: ccc is only present if a reference oscillator is installed.

Example:

<1/CUS?’cr’

>0001/CUS=aaaa;bbbbb;ccc;’cr’’lf’

CUS=

CUS?

CUS=x….x

(See Description of

Arguments)