Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 106
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Serial-based Remote Product Management
Revision 1
5–14
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
Concise
Maintenance
Status
N/A
95 bytes
Query only.
This is the concise version of the RMS command. Returns the Maintenance status of the unit, response is
semicolon delimited, in the form aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;
ooo.o;ppp.p;qqq.q;rrr.r;sss.s;ttt.t where:
aaa.a = P24V1
bbb.b = P24V2
ccc.c = LNBVT (Not applicable on the SPOD)
ddd.d = P13VT
eee.e=P10V1
fff.f = A10V1
ggg.g = A10V2 (see Note)
hhh.h = P7V8T
iii.i = P5V8T
jjj.j = P2V5T
kkk.k = P1V2T
lll.l = N5V8T
mmm.m = FANR1 (see Note)
nnn.n = FANR2 (see Note)
ooo.o = BUCVT (Not applicable on the SPOD)
ppp.p = FWPWR
qqq.q = REFVT (Not applicable on the SPOD)
rrr.r = LNBCS (Not applicable on the SPOD)
sss.s = ATEMP
ttt.t = OTEMP (see Note)
Note: ggg.g, mmm.m, nnn.n, and ttt.t will appear if the appropriate model/options have been selected/installed.
Otherwise, the unused fields will display XXXXX.
CMS=
CMS?
CMS=x….x
(See Description of
Arguments)
Concise Utility
Status
E
N/A
15 bytes
Query only.
Returns the Maintenance status of the unit, response is semicolon delimited, in the form aaaa;bbbbb;ccc where:
aaaa = Remote Unit Address
bbbbb = Remote Baud Rate
ccc = Reference oscillator tuning voltage DAC value (see Note)
Note: ccc is only present if a reference oscillator is installed.
Example:
<1/CUS?’cr’
>0001/CUS=aaaa;bbbbb;ccc;’cr’’lf’
CUS=
CUS?
CUS=x….x
(See Description of
Arguments)