beautypg.com

Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 123

background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Serial-based Remote Product Management

Revision 1

5–31

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

SNMP

Unit Name

SSN=

16 bytes,

characters,

Command or Query.

Sets or returns the SNMP System Name string

Example: <1/SSN=Remote1.

Note: If not configured it returns empty string. <1/SSC=

SSN =

SSN!

SSN?

SSN =x [1..128]

(see Description of

Arguments)

SNMP Trap

Destination IP

Address 1

STA=

15 bytes,

Numerical

Command or Query.

Sets or returns the IP address of the first SNMP Trap destination IP Address 1 where traps will be sent, in the

form xxx.xxx.xxx.xxx

Example: <1/STA=010.006.030.001

Note: When not configured, returns >0001/STA=0.0.0.0

STA =

STA!

STA?

STA=xxx.xxx.xxx.xxx

(see Description of

Arguments)

SNMP Trap

Destination IP

Address 2

STB=

15 bytes,

Numerical

Command or Query.

Sets or returns the IP address of the first SNMP Trap destination IP Address 2 where traps will be sent, in the

form xxx.xxx.xxx.xxx

Example: <1/STB=010.006.030.001

Note: When not configured, returns >0001/STB=0.0.0.0

STB =

STB!

STB?

STB=xxx.xxx.xxx.xxx

(see Description of

Arguments)

SNMP

Trap Version

STV=

1 byte

Command or Query.

Sets or returns the SNMP Trap Version that will be used to send traps.

1=SNMP Trap Version 1

2=SNMP Trap Version 2

Example: <1/STV=0

STV =

STV!

STV?

STV =x

(see Description of

Arguments)

SNMP

Write

Community

SWC=

16bytes,

characters, no

spaces

Command or Query.

Sets or returns the SNMP write community string. Empty string is not allowed

Example: <1/SWC=private

SWC =

SWC!

SWC?

SWC =x

(see Description of

Arguments)

Software Revision N/A

34-37 bytes

Query only.

Returns the value of the internal software revision installed in the unit, in the form:

Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z

-or-

Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz

SWR=

SWR?

SWR=Boot:x.y.zz

Bulk1:x.y.zz

Bulk2:x.y.zz

(See Description of

Arguments)

Set RTC Time

TIM=

6 bytes

Command or Query.

Sets or returns the real-time clock time, from midnight, in the form hhmmss, where:

hh = hours, from 00 to 23

mm = minutes, from 00 to 59

ss = seconds, from 00 to 59

Example (time = 23 hours, 12 minutes and 59 seconds since midnight): <1/TIM=231259’cr’

>0001/TIM=’cr’’lf’

TIM =

TIM?

TIM *

TIM?

TIM=xxxxxx

(See Description of