Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 123

SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Serial-based Remote Product Management
Revision 1
5–31
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
SNMP
Unit Name
SSN=
16 bytes,
characters,
Command or Query.
Sets or returns the SNMP System Name string
Example: <1/SSN=Remote1.
Note: If not configured it returns empty string. <1/SSC=
SSN =
SSN!
SSN?
SSN =x [1..128]
(see Description of
Arguments)
SNMP Trap
Destination IP
Address 1
STA=
15 bytes,
Numerical
Command or Query.
Sets or returns the IP address of the first SNMP Trap destination IP Address 1 where traps will be sent, in the
form xxx.xxx.xxx.xxx
Example: <1/STA=010.006.030.001
Note: When not configured, returns >0001/STA=0.0.0.0
STA =
STA!
STA?
STA=xxx.xxx.xxx.xxx
(see Description of
Arguments)
SNMP Trap
Destination IP
Address 2
STB=
15 bytes,
Numerical
Command or Query.
Sets or returns the IP address of the first SNMP Trap destination IP Address 2 where traps will be sent, in the
form xxx.xxx.xxx.xxx
Example: <1/STB=010.006.030.001
Note: When not configured, returns >0001/STB=0.0.0.0
STB =
STB!
STB?
STB=xxx.xxx.xxx.xxx
(see Description of
Arguments)
SNMP
Trap Version
STV=
1 byte
Command or Query.
Sets or returns the SNMP Trap Version that will be used to send traps.
1=SNMP Trap Version 1
2=SNMP Trap Version 2
Example: <1/STV=0
STV =
STV!
STV?
STV =x
(see Description of
Arguments)
SNMP
Write
Community
SWC=
16bytes,
characters, no
spaces
Command or Query.
Sets or returns the SNMP write community string. Empty string is not allowed
Example: <1/SWC=private
SWC =
SWC!
SWC?
SWC =x
(see Description of
Arguments)
Software Revision N/A
34-37 bytes
Query only.
Returns the value of the internal software revision installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
-or-
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
SWR=
SWR?
SWR=Boot:x.y.zz
Bulk1:x.y.zz
Bulk2:x.y.zz
(See Description of
Arguments)
Set RTC Time
TIM=
6 bytes
Command or Query.
Sets or returns the real-time clock time, from midnight, in the form hhmmss, where:
hh = hours, from 00 to 23
mm = minutes, from 00 to 59
ss = seconds, from 00 to 59
Example (time = 23 hours, 12 minutes and 59 seconds since midnight): <1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
TIM =
TIM?
TIM *
TIM?
TIM=xxxxxx
(See Description of
Arguments)