Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 118
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Serial-based Remote Product Management
Revision 1
5–26
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
Retrieve
Maintenance
Status
N/A
213 bytes,
alpha- numeric
Query only.
Returns maintenance status where:
P24V1 = +24V power supply
P24V2 = +24V switch power supply
LNBVT = +13/18V LNB power supply (Not applicable on the SPOD)
P13VT = +13.5V power supply
P10V1 = +10V1 power supply
A10V1 = 10V1 on RF Module
A10V2 = 10V2 on RF Module (see Note)
P7V8T = +7.8V power supply
P5V8T = +5.8V power supply
P2V5T = +2.5V power supply
P1V2T = +1.2V power supply
N5V8T = -5.8V power supply
FANR1 = Fan 1 speed in percent
FANR2 = Fan 2 speed in percent (see Note)
BUCVT = BUC tuning voltage (Not applicable on the SPOD)
FWPWR = Forward power in dBm
REFVT = Reference osc. tuning voltage (Not applicable on the SPOD)
LNBCS = LNB current supply in mA (Not applicable on the SPOD)
ATEMP = Heatsink temperature in Celsius
OTEMP = Outdoor temperature in Celsius (see Note)
Note: FANR2, A10V2, and OTEMP will appear if the appropriate options are installed; otherwise, the values will report XXXX.
Example: <1/RMS?’cr’
>0001/RMS=’cr’
P24V1=024.1’cr’
P24V2=024.1’cr’
LNBVT=000.0’cr’
P13VT=013.4’cr’
P10V1=010.1’cr’
A10V1=010.1’cr’
A10V2=010.1’cr’
P7V8T=007.8’cr’
P5V8T=005.8’cr’
P2V5T=002.5’cr’
P1V2T=001.2’cr’
N5V8T=-05.7’cr’
FANR1=100.0’cr’
FANR2=100.0’cr’
BUCVT=000.0’cr’
FWPWR=+53.2’cr’
REFVT=001.8’cr’
LNBCS=000.0’cr’
ATEMP=+40.0’cr’
OTEMP=+25.0’cr’
RMS=
RMS?
RMS=x….x
(See Description of
Arguments)