SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Serial-based Remote Product Management

Revision 1

5–26

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Retrieve

Maintenance

Status

N/A

213 bytes,

alpha- numeric

Query only.

Returns maintenance status where:

P24V1 = +24V power supply

P24V2 = +24V switch power supply

LNBVT = +13/18V LNB power supply (Not applicable on the SPOD)

P13VT = +13.5V power supply

P10V1 = +10V1 power supply

A10V1 = 10V1 on RF Module

A10V2 = 10V2 on RF Module (see Note)

P7V8T = +7.8V power supply

P5V8T = +5.8V power supply

P2V5T = +2.5V power supply

P1V2T = +1.2V power supply

N5V8T = -5.8V power supply

FANR1 = Fan 1 speed in percent

FANR2 = Fan 2 speed in percent (see Note)

BUCVT = BUC tuning voltage (Not applicable on the SPOD)

FWPWR = Forward power in dBm

REFVT = Reference osc. tuning voltage (Not applicable on the SPOD)

LNBCS = LNB current supply in mA (Not applicable on the SPOD)

ATEMP = Heatsink temperature in Celsius

OTEMP = Outdoor temperature in Celsius (see Note)

Note: FANR2, A10V2, and OTEMP will appear if the appropriate options are installed; otherwise, the values will report XXXX.

Example: <1/RMS?’cr’

>0001/RMS=’cr’

P24V1=024.1’cr’

P24V2=024.1’cr’

LNBVT=000.0’cr’

P13VT=013.4’cr’

P10V1=010.1’cr’

A10V1=010.1’cr’

A10V2=010.1’cr’

P7V8T=007.8’cr’

P5V8T=005.8’cr’

P2V5T=002.5’cr’

P1V2T=001.2’cr’

N5V8T=-05.7’cr’

FANR1=100.0’cr’

FANR2=100.0’cr’

BUCVT=000.0’cr’

FWPWR=+53.2’cr’

REFVT=001.8’cr’

LNBCS=000.0’cr’

ATEMP=+40.0’cr’

OTEMP=+25.0’cr’

RMS=

RMS?

RMS=x….x

(See Description of

Arguments)