Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 65

background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Ethernet-based Remote Product Management

Revision 1

4–7

Configure HyperTerminal as follows:

1) Be sure to properly define the “Connect To” Telnet connection properties (File

Properties), as shown below at the near right:

Enter the SPOD’s

Management IP Address as

the Host Address (e.g.,

192.168.1.1).

Enter TCP Port 23

as the Port

number.

Set Connect using to TCP/IP

(Winsock) instead of COM1

or COM2.

2) For ASCII Setup (File Properties Settings ASCII Setup), as shown above at the far

right:

A. Check the "Send line ends with line feeds" option in the ASCII Sending section.

B. Check the "Append line feeds to incoming line ends" option in the ASCII Receiving

section.

An example of login and remote command/query execution, when using HyperTerminal as the

interface, appears as follows: