Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 77
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Ethernet-based Remote Product Management
Revision 1
4–19
Serial
• Remote Address – Enter a valid physical remote address from 0001 to 9999.
• Baud Rate – Use the drop-down list to select the operating baud rate as 2400, 4800, 9600,
19200, or 38400 baud
Click [Change Serial Configuration] to save any changes.
Amplifier
•
Amplifier – Use the drop-down list to select the amplifier as either On or Off.
•
Attenuation (dB) – Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps.
•
Attenuation Offset – Enter a valid value, in dB, for the attenuation offset.
•
Fault Recovery – Use the drop-down list to select Fault Recovery as either Automatic or
Manual.
•
Mute – Use the drop-down list to select the Mute function as either Enabled or Disabled.
•
AUX Mute – Use the drop-down list to select the Auxiliary Mute Mode as either Enabled or
Disabled.
•
Offline Mute – Use the drop-down list to select the Offline Mute function as Enabled, or
Disabled.
The MuteRx, MuteTx, MuteRx+LNB, and MuteTx+LNB selections are non-
functional on the SPOD Web Server Interface.
Click [Change Configuration] to save any changes. Otherwise, click [Reset] to revert to the
previously assigned Amplifier settings.
Low Power Forward Threshold (dBm)
Use this field to set the threshold value, in dBm, for the low forward power alarm/fault. When
the forward power monitor is set to Alarm or Fault instead of the factory default of Mask, and
the forward power drops below the specified value, the alarm/fault is indicated.
Setting this parameter to the default value of 00.00 effectively disables the threshold.
Click [Change] to save any changes. Otherwise, click [Reset] to revert to the previously assigned
Low Power Forward Threshold setting.