Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 77

background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Ethernet-based Remote Product Management

Revision 1

4–19

Serial

Remote Address – Enter a valid physical remote address from 0001 to 9999.

Baud Rate – Use the drop-down list to select the operating baud rate as 2400, 4800, 9600,

19200, or 38400 baud

Click [Change Serial Configuration] to save any changes.

Amplifier

Amplifier – Use the drop-down list to select the amplifier as either On or Off.

Attenuation (dB) – Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps.


Attenuation Offset – Enter a valid value, in dB, for the attenuation offset.


Fault Recovery – Use the drop-down list to select Fault Recovery as either Automatic or

Manual.

Mute – Use the drop-down list to select the Mute function as either Enabled or Disabled.


AUX Mute – Use the drop-down list to select the Auxiliary Mute Mode as either Enabled or

Disabled.


Offline Mute – Use the drop-down list to select the Offline Mute function as Enabled, or

Disabled.

The MuteRx, MuteTx, MuteRx+LNB, and MuteTx+LNB selections are non-

functional on the SPOD Web Server Interface.

Click [Change Configuration] to save any changes. Otherwise, click [Reset] to revert to the

previously assigned Amplifier settings.

Low Power Forward Threshold (dBm)

Use this field to set the threshold value, in dBm, for the low forward power alarm/fault. When

the forward power monitor is set to Alarm or Fault instead of the factory default of Mask, and

the forward power drops below the specified value, the alarm/fault is indicated.

Setting this parameter to the default value of 00.00 effectively disables the threshold.

Click [Change] to save any changes. Otherwise, click [Reset] to revert to the previously assigned

Low Power Forward Threshold setting.