Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 115
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Serial-based Remote Product Management
Revision 1
5–23
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
Retrieve Alarm
Status
N/A
168 bytes
Query only.
Returns the alarm status of the unit, where:
OK = no fault condition,
FT = faulted,
AL = alarm,
YS = Yes,
NO = No,
MS = masked,
?? = invalid due to hardware failure,
NA = not applicable because hardware/options not installed.
Example:
<1/RAS?’cr’
>0001/RAS=’cr’
P24V1=OK’cr’ +24V power supply
P24V2=OK’cr’ +24V switch pwr supply
LNBVT=OK’cr’ +13/18V LNB power supply (Not applicable on the SPOD)
P13VT=OK’cr’ +13.5V power supply
P10V1=OK’cr’ +10V power supply
A10V1=OK’cr’ +10V1 RF supply
A10V2=OK’cr’ +10V2 RF supply
P7V8T=OK’cr’ +7.8V power supply
P5V8T=OK’cr’ +5.8V power supply
P2V5T=OK’cr’ +2.5V power supply
P1V2T=OK’cr’ +1.2V power supply
N5V8T=OK’cr’ -5.8V power supply
FANR1=OK’cr’ Fan 1 speed
FANR2=OK’cr’ Fan 2 speed
ATEMP=OK’cr’ Amplifier temperature
SHTDN=OK’cr’ Over-temp shutdown
IICST=OK’cr’ I2C bus status
FWPWR=OK’cr’ Forward power in dBm
CHKSM=OK’cr’ Flash checksum
FPGAD=OK’cr’ FPGA done status
BUCLD=OK’cr’ BUC lock detect (Not applicable on the SPOD)
REFLD=OK’cr’ Reference lock detect (Not applicable on the SPOD)
LNBCS=OK’cr’ LNB current status (Not applicable on the SPOD)
SWITC=OK’cr’ Waveguide switch position status
RDLNK=OK’cr’ Redundant link status
TRMST=YS’cr’’lf’ Terminal Status
Note: A10V1, A10V2, FANR1, FANR2, SWITC and RDLNK will only appear in the list if the appropriate model /
options have been selected / installed.
RAS=
RAS?
RAS=x….x
(See Description of
Arguments)