Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 51
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Updating Firmware
Revision 1
3–3
o
Your Ethernet connection may use either the CAT5 Ethernet adapter cable (CEFD
P/N CA-0000352) to directly connect the User PC Ethernet port to the SPOD, or the
optional LPODnet M&C Netbook Accessory Kit (CEFD Kit KT-0000203). The following
diagram depicts use of the LPODnet for 1:1 Redundant or Standalone Ethernet
connection:
B. On the User PC – If not using the CLC-10, configure the terminal emulator program if
applicable.
Refer to your terminal emulator program HELP feature or user guide for
operating and configuration instructions.
Configure the utility program serial port communication and terminal display operation:
• 38400 bps (Baud Rate)
• 8 Data Bits
• 1 Stop Bit
• Parity = NO
• Port Flow Control =
NONE
• Display New line Rx/Tx: CR
• Local Echo = ON
C. On the SPOD – Power up the unit. Your power connection varies depending on your
ordered unit.
See Sect. 2.3.3 Connector ‘J3 | POWER IN’ (AC Power Mains) or Sect. 2.3.4
Connector ‘J3 | POWER IN’ (DC Power Mains) in this manual for your specific
power connectors.