beautypg.com

Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 22

background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Introduction

Revision 1

1–4

Parameter

Specification

Gain Min (Typical) All Power Levels

70 (75dB)

Input Power Supply Requirements

90-264 VAC, 47-63 Hz, Power Factor Corrected, .96 (typical)

(48 VDC optional)

Max Input level (no damage)

+10 dBm

Gain Adjust

20 dB in 0.25 dB steps

Gain Flatness

±1.5 dB full band (optional ±2.0 dB full band, -50 to +55 °C)

±0.30 dB per 40 MHz (optional ±0.50 dB per 40 MHz, -50 to +55 °C)

Gain variation over temp

±1.5 dB max, -40 to +55 °C (±2.0 dB max, -50 to +55 °C)

Input or Output Return Loss

19.1 dB (1.25:1 VSWR)

Noise Figure

8 to 10 dB typical,15 dB max. @ min. attenuation

RF Mute Isolation

-60 dB min

AM/PM Conversion

2° typical, 3.5° max. @ Rated P1dB output power

Third-order Intermodulation Level

(2 tones, @ -3 dB Total Backoff from P1 dB (-6

dBc SCL), Δ 1MHz)

-30 dBc typical, -25 dBc Guaranteed

Spurious Level

Harmonics

-50 dBc @ Prated – 3 dB

Non-Harmonics Related -65 dBc max.

Group delay variation

Linear

± 0.03 ns/MHz

Parabolic

±0 .003 ns/MHz

2

Ripple

± 1.0 ns pk-pk

Data Logging Parameters

Non-Volatile RAM: Capacity 30 days @ 90 minute intervals.

Includes:

RF Output Power

Mute Status

Heatsink Temperature