Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual
Page 22
SPOD C-, X-, or Ku-Band Outdoor Amplifier
MN-SPODPSX
Introduction
Revision 1
1–4
Parameter
Specification
Gain Min (Typical) All Power Levels
70 (75dB)
Input Power Supply Requirements
90-264 VAC, 47-63 Hz, Power Factor Corrected, .96 (typical)
(48 VDC optional)
Max Input level (no damage)
+10 dBm
Gain Adjust
20 dB in 0.25 dB steps
Gain Flatness
±1.5 dB full band (optional ±2.0 dB full band, -50 to +55 °C)
±0.30 dB per 40 MHz (optional ±0.50 dB per 40 MHz, -50 to +55 °C)
Gain variation over temp
±1.5 dB max, -40 to +55 °C (±2.0 dB max, -50 to +55 °C)
Input or Output Return Loss
19.1 dB (1.25:1 VSWR)
Noise Figure
8 to 10 dB typical,15 dB max. @ min. attenuation
RF Mute Isolation
-60 dB min
AM/PM Conversion
2° typical, 3.5° max. @ Rated P1dB output power
Third-order Intermodulation Level
(2 tones, @ -3 dB Total Backoff from P1 dB (-6
dBc SCL), Δ 1MHz)
-30 dBc typical, -25 dBc Guaranteed
Spurious Level
Harmonics
-50 dBc @ Prated – 3 dB
Non-Harmonics Related -65 dBc max.
Group delay variation
Linear
± 0.03 ns/MHz
Parabolic
±0 .003 ns/MHz
2
Ripple
± 1.0 ns pk-pk
Data Logging Parameters
Non-Volatile RAM: Capacity 30 days @ 90 minute intervals.
Includes:
•
RF Output Power
•
Mute Status
•
Heatsink Temperature