9018 #!ca wrong pos, 9020 param. id wrong, 9022 no network link – Avery Dennison Monarch 9864 Error Messages User Manual
Page 66: 9024 not possible, 9030 log file:cf full, 9031 log file: nnnn, 9032 ep file log stop, 9034 use min 16mb ram, Ca wrong pos, Param. id wrong

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
66
9018
#!CA wrong Pos.
Status
The #!CA command is placed at an invalid position – Easy Plug cannot
process the command at this position (for example, while loading files onto
a Compact Flash card).
Action
Call the #!CA command at a valid position.
9020
Param. ID wrong
Status
A non-existing parameter ID was used.
Action
Correct the parameter ID.
9022
No network link
Status
This message occurs when the Ethernet address assign is set to DHCP.
The cause is usually a bad network connection.
Action
Check if the network connector is plugged in properly.
9024
Not possible !
Status
Detecting the material length (a function, which is normally used with MLI is
not possible, because a printjob is currently processed).
Action
Retry as soon as the printjob is processed.
9030
Log file:CF full
Status
An attempt to store data on the Compact Flash card was not successful,
because of a full card.
Action
Clear some storage space on the Compact Flash card.
Load an empty card.
9031
Log file: nnnn
Status File
access
error.
nnnn = error code of the operating system.
Action
Repeat the operation. If the message reappears, send a message to
Service including the error code.
9032
EP file log stop
Status
Someone tried to send data after an error message appeared. This
deactivates the Easy Plug file logging.
Action
Reactivate the file logging.
9034
Use min 16MB RAM
Status
The printer does not have enough RAM. The applied firmware version
needs at least 16 MB RAM for operation.
Action
Extend the printer's RAM.