beautypg.com

1038 software error, 1087 olv not active, 1088 no realtimeclock – Avery Dennison Monarch 9864 Error Messages User Manual

Page 13: 1089 seek fkt. error, 1090 incomplete job, 1091 wrong var field, 1092 rename file, Software error, Olv not active, No realtimeclock

background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

13

1038 Software

error

Status

General software error

Action

Turn off the printer, wait 30 seconds, then turn it back on.

See notes in “General software errors” section.

1087 OLV

not

active

Status

Verifier-specific Easy Plug commands have been used (#OLVI or #OLVD),
without having set the printer to use a verifier.

Action

Set the printer to verifier use.

See parameter

INTERF. PARAM > COM2 PORT > Function Option

.

1088 No

realtimeclock

Status

Realtime clock-specific Easy Plug commands have been used (#YS or
#YC), without having a realtime clock installed.

Action

Install a realtime clock.

1089

Seek Fkt. Error

Status

General software error. An error occurred while processing the seek
function in the printer's internal file system.

Action

Press Online to acknowledge.

Please read the notes in section "General software errors".

1090 Incomplete

Job

Status

The actual print job is not terminated by the #Q command. The start
command #ER for a label format follows another #ER command without the
first format ending with #Q.

Action

Press Online to acknowledge.

End the print job with a #Q command.

1091

Wrong var field

Status

An error occurred while interpreting the text string of a variable data field.
The error could be caused by a #YT or a #YB command (Easy Plug).
Self-acknowledging error.

Action

Check the text strings of variable data fields.

1092 Rename

file

Status

General software error

Action

See notes in “General software errors” section.