1038 software error, 1087 olv not active, 1088 no realtimeclock – Avery Dennison Monarch 9864 Error Messages User Manual
Page 13: 1089 seek fkt. error, 1090 incomplete job, 1091 wrong var field, 1092 rename file, Software error, Olv not active, No realtimeclock
![background image](https://www.manualsdir.com/files/772970/content/doc013.png)
05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
13
1038 Software
error
Status
General software error
Action
Turn off the printer, wait 30 seconds, then turn it back on.
See notes in “General software errors” section.
1087 OLV
not
active
Status
Verifier-specific Easy Plug commands have been used (#OLVI or #OLVD),
without having set the printer to use a verifier.
Action
Set the printer to verifier use.
See parameter
INTERF. PARAM > COM2 PORT > Function Option
.
1088 No
realtimeclock
Status
Realtime clock-specific Easy Plug commands have been used (#YS or
#YC), without having a realtime clock installed.
Action
Install a realtime clock.
1089
Seek Fkt. Error
Status
General software error. An error occurred while processing the seek
function in the printer's internal file system.
Action
Press Online to acknowledge.
Please read the notes in section "General software errors".
1090 Incomplete
Job
Status
The actual print job is not terminated by the #Q command. The start
command #ER for a label format follows another #ER command without the
first format ending with #Q.
Action
Press Online to acknowledge.
End the print job with a #Q command.
1091
Wrong var field
Status
An error occurred while interpreting the text string of a variable data field.
The error could be caused by a #YT or a #YB command (Easy Plug).
Self-acknowledging error.
Action
Check the text strings of variable data fields.
1092 Rename
file
Status
General software error
Action
See notes in “General software errors” section.