Messages which can only occur with RFID option
5502 RFID
internal
Status
General software error
Action
See notes in “General software errors” section.
5504 No
RFID
job
Status
A print job, which is not defined as RFID printjob, contains RFID-specific
Easy Plug commands (e. g. #RT, #RFW, …).
RFID printjobs are defined in the #IM command by defining the distance
between label edge and transponder antenna (parameter "d").
Action
Change the print job.
5510
RFID COM timeout
Status
Timeout error. There was no communication between the reader module
and COM2 in the given time frame.
Action
Repeat the operation that caused the error.
Check if the reader module board is properly connected.
Check if the reader module board is defective.
5512
COM open failed
Status
There was a communication problem at COM2 while powering up the
printer. The interface cannot be opened by the printer firmware – or it is
used by another firmware part.
Action
Check if COM2 is available.
Check the function of the COM2 interface.
5513
Get baud failed
Status
There was a communication problem between COM2 and the reader
module while powering up the printer. The baud rate of the reader module
is not detected correctly by the printer firmware. Baud rate and/or parity
and/or another setting of transmission parameters at the reader module is
faulty.
Action
Check if the reader module board is connected correctly.
Check if the reader module board is defective.
Check the setting of the transmission parameters at the reader module.
5521 No
transponder
Status
Either there is no transponder (tag) or more than one transponder within
reach of the antenna.
Action