3004 rs232 parity, 3005 rs232 frame, 3010 spooler overflow – Avery Dennison Monarch 9864 Error Messages User Manual
Page 32: 3011 send buffer full, Rs232 parity, Rs232 frame, Spooler overflow, Send buffer full

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
32
Action
Press Online to acknowledge.
3004 RS232
Parity
Status
Receive error at the RS232 interface COM2 (parity).
Action
Press Online to acknowledge.
Check parameter setting at printer (
INTERF. PARAM. > COM2 PORT > Parity
) and
PC.
See the User Manual for more information about printer parameters.
3005 RS232
Frame
Status
Receive error at the RS232 interface COM2 (frame).
Action
Press Online to acknowledge.
Check parameter setting at printer (
INTERF. PARAM. > COM2 PORT > Baud rate
and
INTERF. PARAM. > COM1 PORT > stop bits
) and PC.
See the User Manual for more information about printer parameters.
3010 Spooler
Overflow
Status
Error caused by a faulty handshake at a serial or Centronics interface. Data
overflows the printer's data buffer, because the host does not stop sending
data to the printer.
Action
Press Online to acknowledge.
Check the connections of the data line, especially the signal wires
belonging to the handshake.
3011
Send buffer full
Status
The send buffer is full. This error may occur when the printer status is
requested several times (#!Xn), but the status reply is not read out.
Action
Make sure the status reply is read out.