9005 no printhead, 9007 bad mac address, 9009 temporary mac – Avery Dennison Monarch 9864 Error Messages User Manual
Page 64: 9011 bootloader ext, No printhead, Bad mac address, Temporary mac, Bootloader ext

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
64
9005 No
Printhead
Status
Printhead could not be detected for one of the following reasons:
- Printhead cable not connected
- Wrong printhead type
- Defective printhead cable
- Defective CPU board
- Printhead cable plugged into wrong connector on the CPU board
Action
Check printhead cable, printhead and CPU board, and replace defective
parts.
9007
Bad MAC Address
Status
This error message appears when an invalid MAC address is programmed
to the CPU board. Valid means the MAC address matches the range
00.0a.44.xx.xx.xx.
In this case, the network is not initialized. To work with the network, a valid
(Avery-) MAC address must be programmed on the board. This can only be
done by an authorized service technician or by the factory.
Action
Press Online to acknowledge. The printer starts, but cannot be used with a
network.
Contact Service for help reprogramming the boards MAC address.
If new programming is not possible, exchange the CPU board.
9009 Temporary
MAC
Temporary
MAC
address.
Status
This error message appears when the MAC address has the value
00.0a.44.00.00.00. This MAC address is used only during production.
Action
Press Online to acknowledge. The printer starts and the network can be
used.
Contact Service for help reprogramming the boards MAC address.
If new programming is not possible, exchange the CPU board.
9011 Bootloader
ext.
Bootloader external device.
Status
At least one external device (AI, BLDC output stage) has no valid
application loaded. The printer remains in the bootloading status and
returns this message. The error only occurs if an AI is applied.
Action
Load a valid application.