2006 exp.functionname, 2007 exp.fct.paratype, 2008 exp.fct.paracnt – Avery Dennison Monarch 9864 Error Messages User Manual
Page 31: 2009 exp. name wrong, 3000 rs232 overrun, 3001 rs232 parity, 3002 rs232 frame, 3003 rs232 overrun, Exp.functionname, Exp.fct.paratype

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
31
2006 Exp.functionname
Status
A wrong function name is used in the expression.
Action
Check if the function names used in the expression are spelled correctly
and if the functions exist. Change the function name.
2007 Exp.fct.paratype
Status
A wrong parameter type in an expression was detected.
Example: SubStr(“Text”,o,”A”) causes an error because “A” is not a
number.
Action
Check the expression and correct it.
2008 Exp.fct.paraCnt
Status
Wrong number of function parameters in the expression.
Action
Check the expression and correct it.
2009
Exp. name wrong
Status
An undefined variable name is used in an expression.
Action
Check the variable names and correct the spellling or define a new
variable.
3000 RS232
Overrun
Status
Receive error at the RS232 interface COM1 (overrun).
Action
Press Online to acknowledge.
3001 RS232
Parity
Status
Receive error at the RS232 interface COM1 (parity).
Action
Press Online to acknowledge.
Check parameter setting at printer (
INTERF. PARAM. > COM1 PORT > Parity
) and
PC.
See the User Manual for more information about printer parameters.
3002 RS232
Frame
Status
Receive error at the RS232 interface COM1 (frame).
Action
Press Online to acknowledge.
Check parameter setting at printer (
INTERF. PARAM. > COM1 PORT > Baud rate
and
INTERF. PARAM. > COM1 PORT > stop bits
) and PC.
See the User Manual for more information about printer parameters.
3003 RS232
Overrun
Status
Receive error at the RS232 interface COM2 (overrun).