2006 Exp.functionname

Status

A wrong function name is used in the expression.

Action

Check if the function names used in the expression are spelled correctly

and if the functions exist. Change the function name.

2007 Exp.fct.paratype

Status

A wrong parameter type in an expression was detected.

Example: SubStr(“Text”,o,”A”) causes an error because “A” is not a
number.

Action

Check the expression and correct it.

2008 Exp.fct.paraCnt

Status

Wrong number of function parameters in the expression.

Action

Check the expression and correct it.

2009

Exp. name wrong

Status

An undefined variable name is used in an expression.

Action

Check the variable names and correct the spellling or define a new

variable.

3000 RS232

Overrun

Status

Receive error at the RS232 interface COM1 (overrun).

Action

Press Online to acknowledge.

3001 RS232

Parity

Status

Receive error at the RS232 interface COM1 (parity).

Action

Press Online to acknowledge.

Check parameter setting at printer (

INTERF. PARAM. > COM1 PORT > Parity

) and

PC.

See the User Manual for more information about printer parameters.

3002 RS232

Frame

Status

Receive error at the RS232 interface COM1 (frame).

Action

Press Online to acknowledge.

Check parameter setting at printer (

INTERF. PARAM. > COM1 PORT > Baud rate

and

INTERF. PARAM. > COM1 PORT > stop bits

) and PC.

See the User Manual for more information about printer parameters.

3003 RS232

Overrun

Status

Receive error at the RS232 interface COM2 (overrun).