8302 barcode checksum, 8303 bar code sample, 8304 bar c. plain-copy – Avery Dennison Monarch 9864 Error Messages User Manual
Page 57: 8305 bar code print, 8306 plain-copy len, 8307 readline dist, 8308 bar code ratio, 8309 module range, Barcode checksum, Bar code sample
05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
57
8302 Barcode
checksum
Status
Error while calculating the bar code check sum.
Action
Check transmitted data.
If the error continues to occur, contact Service. Send the transmitted Easy
Plug data.
8303
Bar code sample
Status
Error while calculating the bar code sample.
Action
Check whether the transmitted data is valid for the bar code type and
change the data.
8304
Bar c. plain-copy
Status
Error while integrating the plain-copy line in the bar code sample.
Action
Check whether the transmitted data is valid for the bar code type and
change the data.
8305
Bar code print
Status
Error while calculating the bar code print image.
Action
Press Online to acknowledge.
Action
Check whether the transmitted data is valid for the bar code type and
change the data.
8306 Plain-copy
len.
Status
Illegal: bar code plain-copy line has more than 300 characters.
Action
Reduce line length.
8307 Readline
dist.
Status
General software error.
Action
Turn off the printer, wait 30 seconds, then turn it back on.
See notes in “General software errors” section.
8308
Bar code ratio
Status
Illegal bar code ratio.
Action
Select another ratio.
8309 Module
range
Status
Maximum range of the bar code module exceeded.
Action
Reduce module range.