Error Messages
9844 – 9854 – 9864
41
5100
No H8 response
Status
Error while performing the "Sensor Test" function.
Action
Press Online to acknowledge.
Contact Service.
Instructions
for
Service:
The error can occur in connection with the exchange of the CPU board of
an ALX 92x machine.
Acknowledge error, set all sensors, restart.
If the error message still appears: Reload firmware and/or perform a forced
bootloader start with "Clear params".
If the error continues to appear, send us the CPU board with a fault
description.
5101 Headadjust
error
Status
Error while performing the "Head Alignment" function.
Action
Press Online to acknowledge.
Contact Service.
5102 Dot
Defective
Status
Defective printhead dot detected while performing the "Head dot test"
function.
Action
Press Online to acknowledge.
5120 Home
position
Status
The applicator cannot reach the home position. The stacker has been
moved and the stepper motor loses steps and does not regain the home
position.
Preconditions for this error to occur:
•
The parameter
DP INTERFACE > Interface type
is set to USI Applicator.
•
Internal inputs are enabled.
Action
Do not forcefully move the applicator.
Press Online to acknowledge.