5100 no h8 response, 5101 headadjust error, 5102 dot defective – Avery Dennison Monarch 9864 Error Messages User Manual

Page 41: 5120 home position, No h8 response, Headadjust error, Dot defective, Home position

background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

41

5100

No H8 response

Status

Error while performing the "Sensor Test" function.

Action

Press Online to acknowledge.

Contact Service.

Instructions

for

Service:

The error can occur in connection with the exchange of the CPU board of
an ALX 92x machine.

Acknowledge error, set all sensors, restart.

If the error message still appears: Reload firmware and/or perform a forced

bootloader start with "Clear params".

If the error continues to appear, send us the CPU board with a fault

description.

5101 Headadjust

error

Status

Error while performing the "Head Alignment" function.

Action

Press Online to acknowledge.

Contact Service.

5102 Dot

Defective

Status

Defective printhead dot detected while performing the "Head dot test"
function.

Action

Press Online to acknowledge.

5120 Home

position

Status

The applicator cannot reach the home position. The stacker has been
moved and the stepper motor loses steps and does not regain the home
position.

Preconditions for this error to occur:

The parameter

DP INTERFACE > Interface type

is set to USI Applicator.

Internal inputs are enabled.

Action

Do not forcefully move the applicator.

Press Online to acknowledge.