1512 code128 mode err, 1513 wrong mode, 1514 ^bx parm err – Avery Dennison Monarch 9864 Error Messages User Manual
Page 27: 1515 conv to ecc200, 1516 bad drive: x, 1517 mask string: x, 1518 bad format: x, Code128 mode err, Wrong mode, Bx parm err

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
27
1512 Code128
Mode
Err
Error level
1
Status
Code128 barcode command specifying mode type other than 'AUTO'.
Action
Change the bar code command.
1513 Wrong
Mode
Error level
2
Status
Coda block barcode command specifying mode type other than 'F'.
Action
Change the bar code command.
1514
^BX Parm Err.
Error level
2
Status
Data Matrix bar code command specified an escape sequence character.
This is not supported.
Action
Change the bar code command.
1515
Conv to ECC200
Error level
1
Status
Data Matrix bar code command specified non ECC200 level. Program tries
to convert to ECC200.
Action
Change the bar code command.
1516
Bad Drive: x
Error level
2
Status
The drive selected is not a valid drive. (We support only 'R' and 'B' while
MLI supports 'R', 'B', 'Z' and 'E').
Action
Select a valid drive.
1517
Mask String: x
Error level
2
Status
The mask string used in ^SF command is not supported.
Action
Change the print job.
1518
Bad Format: x
Error level
2
Status
The graphic format selected is not supported (Compressed binary and PNG
format).
Action
Convert graphic to a supported format.