05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

45

5131 PSU

communicat.

Power supply communication

(9864 only)

Status

An error occurred during communication with the power supply via I

2

C bus.

Action

Turn off the printer, wait 30 seconds, then turn it back on. If the error

message continues to appear, contact Service.

5150

No USI interface

Status

(DPM / PEM / ALX 92x only)
This error appears if no USI is detected while the printer is powering up.

Action

Check if the USI is defective or not built in.

5151 Applic.

interf.

Applicator

interface

Status

(DPM / PEM / ALX 92x only)

Neither Applicator Interface (AI), nor USI are connected to the device.

Action

Connect a USI or AI to the device.

5200 Home

position

Status

The applicator did not reach its home position within the given time frame.

Possible

causes:

The applicator is jammed

Applicators driven by compressed air – the air supply may be interrupted or

turned off

Cable not properly connected

Action

Check cable and compressed air connections; reconnect them properly.

Remove any obstacles around the applicator.

5201 Touch

down

Status

The applicator did not reach its touch down position within the given time
frame.

Action

Check cable and compressed air connections; reconnect them properly.

Remove any obstacles around the applicator.

5203

Touch down sens.

Status

The touchdown sensor(s) was/were already triggered before the
application.

Action

Check cable and compressed air connections; reconnect them properly, if

necessary.