USER MANUAL
Error Messages
9844 – 9854 – 9864
45
5131 PSU
communicat.
Power supply communication
(9864 only)
Status
An error occurred during communication with the power supply via I
2
C bus.
Action
Turn off the printer, wait 30 seconds, then turn it back on. If the error
message continues to appear, contact Service.
5150
No USI interface
Status
(DPM / PEM / ALX 92x only)
This error appears if no USI is detected while the printer is powering up.
Action
Check if the USI is defective or not built in.
5151 Applic.
interf.
Applicator
interface
Status
(DPM / PEM / ALX 92x only)
Neither Applicator Interface (AI), nor USI are connected to the device.
Action
Connect a USI or AI to the device.
5200 Home
position
Status
The applicator did not reach its home position within the given time frame.
Possible
causes:
•
The applicator is jammed
•
Applicators driven by compressed air – the air supply may be interrupted or
turned off
•
Cable not properly connected
Action
Check cable and compressed air connections; reconnect them properly.
Remove any obstacles around the applicator.
5201 Touch
down
Status
The applicator did not reach its touch down position within the given time
frame.
Action
Check cable and compressed air connections; reconnect them properly.
Remove any obstacles around the applicator.
5203
Touch down sens.
Status
The touchdown sensor(s) was/were already triggered before the
application.
Action
Check cable and compressed air connections; reconnect them properly, if
necessary.