beautypg.com

5204 start delay, 5205 applicator gen, 5206 applicator resp – Avery Dennison Monarch 9864 Error Messages User Manual

Page 46: 5207 appl. driver 1, 5208 appl. driver 2, 5209 appl. driver 3, 5210 appl. driver 4, 5500 unknown, 5501 general, Start delay

background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

46

5204 Start

delay

Status

The applicator received another start signal while printing/applying a label.

Precondition: Parameter

APPLICATOR PARA > Start error stop

or

DP INTERFACE > Start error stop

is set to On.

Action

Check the labelling procedure, increase the product distance.

Set parameter Start error stop to Off.

5205 Applicator

gen.

Status

General software error

Action

See notes in “General software errors” section.

5206 Applicator

resp.

Status

Communication with the AI exceeded a given time frame.

Action

Turn off the printer and on again after 30 seconds. If the error still occurs

after several tries, contact Technical Support.

5207

Appl. driver 1

Status

Shortcut or overheat at power output 1 of the AI.

Action

Check the connections.

5208

Appl. driver 2

Status

Shortcut or overheat at power output 2 of the AI.

Action

Check the connections.

5209

Appl. driver 3

Status

Shortcut or overheat at power output 3 of the AI.

Action

Check the connections.

5210

Appl. driver 4

Status

Shortcut or overheat at power output 4 of the AI.

Action

Check the connections.

5500 Unknown

Status

General software error

Action

See notes in “General software errors” section.

5501 General

Status

General software error

Action

See notes in “General software errors” section.