xxxxxxxx
Status
Power supply failure. "xxxxxxxx" = four byte long error code in hexadecimal
form. Every bit stands for a certain status of the power supply. The bit is set
to "1" if the status occurred.
•
Byte 1: xxxxxxxx
x
x
7 6 5 4 3 2 1 0
Output 1 (5 V logic):
The output voltage exceeds the
range.
Output 2 (20-28 V printhead):
The output voltage exceeds the
range.
Output 3 (galv. 24 V):
The output voltage exceeds the
range.
Output 4 (48 V motor):
The output voltage exceeds the
range.
Dot Check defective:
Indicates a detected power supply
error in the course of a Dot-Check-
Action. Example: While measuring
the internal reference resistance, the
tolerances are exceeded.
Fan defective:
Indicates a fan error. Its control
allows any error detection.
Critical overheat:
A critical temperature is set in
register "critical temperature limit". If
the critical value is exceeded, the
power supply turns off immediately
and sets this bit to 1.
Overheat:
A critical temperature is set in
register "critical temperature limit". If
the critical value is exceeded, the
power supply turns off immediately
and sets this bit to 1.