beautypg.com

5130 psu xxxxxxxx, Psu xxxxxxxx – Avery Dennison Monarch 9864 Error Messages User Manual

Page 43

background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

43

5130 PSU

xxxxxxxx

Status

Power supply failure. "xxxxxxxx" = four byte long error code in hexadecimal
form. Every bit stands for a certain status of the power supply. The bit is set
to "1" if the status occurred.

Byte 1: xxxxxxxx

x

x

7 6 5 4 3 2 1 0

Output 1 (5 V logic):
The output voltage exceeds the
range.

Output 2 (20-28 V printhead):
The output voltage exceeds the
range.

Output 3 (galv. 24 V):
The output voltage exceeds the
range.

Output 4 (48 V motor):
The output voltage exceeds the
range.

Dot Check defective:
Indicates a detected power supply
error in the course of a Dot-Check-
Action. Example: While measuring
the internal reference resistance, the
tolerances are exceeded.

Fan defective:
Indicates a fan error. Its control
allows any error detection.

Critical overheat:
A critical temperature is set in
register "critical temperature limit". If
the critical value is exceeded, the
power supply turns off immediately
and sets this bit to 1.

Overheat:
A critical temperature is set in
register "critical temperature limit". If
the critical value is exceeded, the
power supply turns off immediately