4106 olv software, 5000 bus device, Olv software – Avery Dennison Monarch 9864 Error Messages User Manual
Page 34: Bus device

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
34
4106 OLV
Software
Status
General software error
Action
See notes in “General software errors” section.
5000 Bus
device
Status
One of the devices connected to the I
2
C bus (output stage boards) does not
respond. This message appears first in a sequence of two or three
messages, which helps isolate the error source.
Action
Press Online to acknowledge.
Turn off the printer, wait 30 seconds, then turn it back on. If the error
message continues to appear, please contact Service.
Example The
parameter
SYSTEM PARAMETERS > Periph. device
is set to "Cutter" without
a cutter output stage board installed. The following messages appear one
after another:
1. Status 5000
Bus device
Error with the I
2
C bus communication.
Press Online.
2. Status 5005
Knife-fault
Either no cutter output stage board is installed
or the I
2
C bus data cable is not connected to
Press Online.
3. Status 5020
I2C Timeout 4
Time limit exceeded without a response from
the cutter (4 = Cutter, see 0).
Press Online.
One of the following messages may appear next:
Status # Text
Missing output stage for the following
device:
Knife-fault Cutter
motor
Head-fault
Printhead lift motor
Ribbon end
Ribbon motor
Tab. 2 I
2