beautypg.com

4106 olv software, 5000 bus device, Olv software – Avery Dennison Monarch 9864 Error Messages User Manual

Page 34: Bus device

background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

34

4106 OLV

Software

Status

General software error

Action

See notes in “General software errors” section.

5000 Bus

device

Status

One of the devices connected to the I

2

C bus (output stage boards) does not

respond. This message appears first in a sequence of two or three
messages, which helps isolate the error source.

Action

Press Online to acknowledge.

Turn off the printer, wait 30 seconds, then turn it back on. If the error

message continues to appear, please contact Service.

Example The

parameter

SYSTEM PARAMETERS > Periph. device

is set to "Cutter" without

a cutter output stage board installed. The following messages appear one
after another:

1. Status 5000

Bus device

Error with the I

2

C bus communication.

Press Online.

2. Status 5005

Knife-fault

Either no cutter output stage board is installed
or the I

2

C bus data cable is not connected to

the board (see Tab. 2)

Press Online.

3. Status 5020

I2C Timeout 4

Time limit exceeded without a response from
the cutter (4 = Cutter, see 0).

Press Online.

One of the following messages may appear next:

Status # Text

Missing output stage for the following
device:

5005

Knife-fault Cutter

motor

5006

Head-fault

Printhead lift motor

5008

Ribbon end

Ribbon motor

Tab. 2 I

2