beautypg.com

Avery Dennison Monarch 9864 Error Messages User Manual

Page 44

background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

44

Byte 2: xxxxxxxx

x

x

7 6 5 4 3 2 1 0

Reserved (must be 0):
Shows an error bit, which is provided
by the printer controller.

Reserved (must be 0):
Shows an error bit, which is provided
by the printer controller.

not used

not used

not used

Temperature sensor defective:
The Action at the A/D-converter
leads to a temperature below –20°C
or over +170°C. All outputs except
the logic supply are turned off.

Operation time counter:
Inconsistent data with the operation
time counter.

EEPROM error:
Data content of the EEPROM is not
consistent.

Byte 3: xxxxxxxx

x

x

(can only be 00H or F0H)

7 6 5 4 3 2 1 0

not used

not used

not used

not used

not used

not used

not used

I

2

C transfer error

Byte 4: xxxxxxxx (not used)

Example: 0000F020 means: "EEPROM error" and "Fan defective".