Echelon Lumewave CRD 3000 Street Light Bridge User Manual
Page 95
Street Light Bridge Integrator’s Guide
85
Controller tree below the iLON App (Internal) device. You can then click the
functional block and begin configuring the Event Scheduler application.
To create a Scheduler functional block and open the application, perform the
following steps:
1. Expand the Net network icon in the Segment Controller tree, and expand
the LON channel to show the iLON App (Internal) device.
2. Right-click the iLON App (Internal) device, and select Add
Functional Block from the shortcut menu.
3. The Add Functional Block dialog opens.
4. Select the Scheduler functional block from the Static or Dynamic
L
ON
M
ARK
folder. The folder available in the dialog depends on whether
the Segment Controller is using the static v12 external interface (XIF)
file or the dynamic v40 XIF file.
•
If the Segment Controller is using the static v12 XIF file (the
default), expand the Static icon, select the Scheduler functiona1
block, optionally enter a different name than the default
programmatic functional block name, and then click OK.