Entering the location of the segment controller, Manually configuring the time – Echelon Lumewave CRD 3000 Street Light Bridge User Manual
Page 92

82
Controlling a Street Lighting Network
7. Click Submit to save the changes.
Manually Configuring the Time
You can manually configure the Segment Controller’s real-time clock:
1. Right-click the Segment Controller icon, select Setup, and select Time
from the shortcut menu.
Alternatively, you can click Tools and then select Time to configure the
time settings on the local Segment Controller.
2. The Setup Time Web page opens.
3. In the Timezone property, select the time zone in which the Segment
Controller is located.
4. In the Date and Local Time property, enter the time and date to be stored
in the Segment Controller's real time clock. You might need to refresh the
Web page to view the current time.
5. Click Submit to save the changes.
Note that if the Last Sync Time property does not show a valid timestamp for
the SNTP server’s most recent synchronization (for example, if it shows
“Unknown”), it is likely that the configuration for the SNTP server is incorrect.
Check that the server name is correct and that port 123 is available.
Entering the Location of the Segment Controller
You can enter the geographic coordinates of the Segment Controller: