Error codes – Echelon Lumewave CRD 3000 Street Light Bridge User Manual
Page 55

Street Light Bridge Integrator’s Guide
45
Street Light Bridge module is powered on; any time spent powered off is not
included in this timeout value.
Because the Street Light Bridge application writes the remaining error
simulation time to onboard flash memory once every 30 minutes, completion of
error simulation might be delayed by up to 30 minutes if the CRD 3000 Street
Light Bridge module is powered off or reset during the simulation.
Updating the nviErrRate data point has the following effect:
•
If error simulation is active, the error simulation expiration timer is
restarted with the current nciErrTimeout value. Note that setting the
nviErrRate data point to zero still causes the error simulation
expiration timer to restart, even though no errors are simulated.
•
If error simulation is not active, the value is stored but has no other
immediate effect.
Updating the nviErrMode data point has the following effect:
•
If error simulation is active, and if nviErrMode is not all zeroes, the
error simulation expiration timer is restarted with the current
nciErrTimeout value.
•
Setting nviErrMode to all zeroes ends error simulation mode, regardless
of how much time remains.
Updating the nciErrTimeout data point has the following effect:
•
If error simulation mode is active, error simulation mode is restarted
with the new timeout value, regardless of how much time has already
passed or how much time would be left in the previous simulation.
•
If error simulation mode is not active, the value is stored but has no other
immediate effect.
Note that a value of zero (0) is not valid for the nciErrTimeout data point; the
Street Light Bridge application rounds a zero value up to 1 (one) to ensure that
error simulation mode can eventually end.
Error Codes
The Segment Controller displays the last error code on the Web page for the CRD
3000 Street Light Bridge module. You can also use network management tools to
send a query status message to the CRD 3000 Street Light Bridge module to
retrieve the error log. See the Neuron Tools Errors Guide (078-0402-01B) for a
listing of Neuron firmware error codes. The Street Light Bridge firmware can