Street Light Bridge Integrator’s Guide
81
6. Configure the following time (SNTP) server properties:
Time Server Port
The port used by the Segment Controller to receive time data.
The default value is 123, and it cannot be changed. Contact
your IT department to make sure that your firewall is
configured to allow you to access the time server on this port.
Time
Synchronization
Mode
Select the frequency in which the Segment Controller is
synchronized to the SNTP server:
•
Automatic. The Segment Controller is synchronized every
1 to 15 minutes and remains within 100 ms of the SNTP
server. This is the default, and it can be used for both LAN
and dial-out (modem and GPRS) connections.
•
Sync when Dial-Up is active. The Segment Controller
clock is synchronized when a dial-out connection is
established. This option can only be used for dial-out
connections (modem and GPRS).
•
Fixed Interval. The frequency in which the Segment
Controller is synchronized is based on the value in the
Synchronization Interval property. This option can only
be used for Ethernet connections.
•
Disabled. The Segment Controller is not synchronized with
the SNTP server.
Time
Synchronization
Interval
Set how often the Segment Controller clock is synchronized with
the SNTP server. This option is only available if Fixed
Interval is the selected synchronization method. The default
synchronization interval is 12 hours.
Use As
Select whether this time server is the Default or the Backup
time server. If this is the first time service created on the
Segment Controller, this option is set to Default. If another
time service is currently designated as the default and you
select Default, the default designation will be removed from the
other time server when you click Submit.