Multi card open – FingerTec Ingress User Manual
Page 34
34
3.
Name
the Zone, e.g.: R&D office.
4. Click
Add Device
.
5.
Select
Ingressus from the list.
6.
Name
the Ingressus controller.
7. Press
Edit
at the Zone panel.
8. Select
Time Set
to access for access. No access granted if time falls out of the boundary.
9. Click
Add Personnel
to define the user as First Card Unlock person (he/she still can use
password or fingerprint to verify). It is optional to assign more than 1 user.
10. Click
Add Door
to define which Ingressus to follow this rule.
11. Press
Save
to save settings.
12.
Sync
settings to the Ingressus controller.
Multi card open
Multi card open is a security feature to unlock doors whereby at least 2 specified users must
verify themselves (fingerprint, password or card) at the same time at a door to gain access.
You can set up to a maximum of 5 users that must verify together to unlock a door.
1. Click
Multi Card Open
from the left panel.
2. Click
Add User Group
.
3.
Name
the User Group e.g.: R&D group.
4. Click
Edit
at the right panel.
5.
Select
the relevant users from the list.
6. Click
Save
to save settings.
7. Click
Multi
Card Combination Group
from the left panel.
8. Click
Add Combination Group
.
9.
Name
the Combination Group e.g.: Restricted Area – Level 1.