beautypg.com

FingerTec s-Kadex Installation Guide User Manual

S-kadex, Installation guide, Stand-alone card & password access control system

background image

w w w . f i n g e r t e c . c o m

w w w . f i n g e r t e c . c o m

Installation Guide

3

2

4

1

WIRING FOR POWER SUPPLY

The power input ports for these models are located at the rear of the terminals. There is no adapter plug
supplied with the models, instead you need to source for power cables (red and black cables) to connect
the power from the terminal to a power supply.

CONFIGURING THE SECURITY SETTINGS

After determining the height of the
terminal from the ground level and
making the relevant marks on the
wall, drill the screws into the wall to
hang the back plate.

Refer to Appendix for dimensions
and measurements of installation.

Back of Terminal

For NC or NO

door lock

system

BUT

GND

SEN

NO1

COM1

NO1

DC12V

Power Supply

+12V

GND

POWER SUPPLY PORT

Alarm

device

Type NO

AL_

AL+

Door

bell

BELL_

BELL+

.

.

.

.

.

.

.

.

.

.

.

.

DETERMINE THE LOCATION AND POSITIONING OF THE INSTALLATION

• Avoid installing the terminals in locations with high moisture or condensation levels in the air.
• The recommended installation height of the terminal from the ground is 1.2 meter.

MOUNTING OF TERMINALS ON A WALL

ADJUST DOOR UNLOCK TIME

Adjust time for device to unlock according to your
preference.

Operation: Verify your Admin password > Press 4 >
Green LED blinks > Buzzer emits long beep > Insert time
in seconds, i.e. 10 > Green LED blinks > Buzzer emits long
beep > Timer adjusted successfully

Note: The maximum unlock time is 254s. If you want to insert values
less than 3-digits, hash (#) is required. E.g.: 10 will be keyed in as 10#.

SELECT DOOR SENSOR TYPE

Installing a door sensor is important to monitor door
activity. Select the type (NO or NC) before it starts to work.

Operation: Verify your Admin password > Press 0 >
Green LED blinks > Buzzer emits long beep > Press 5 >
Green LED blinks > Buzzer emits long beep > Press
number to select type of door sensor > Green LED blinks
> Buzzer emits long beep > Changes done successfully

Note:

NO

Type

0

NC

Type

1

Disable

door

sensor

2

ADJUST DOOR SENSOR DELAY TIME

Set time to allow door to remain open after unlocking.
The device alerts you with a buzzer sound when the
allowed time runs out.

Operation: Verify your Admin Password > Green LED
blinks > Buzzer emits long beep > Press 0 > Green LED
blinks > Buzzer emits long beep > Press 4 > Green LED
blinks > Buzzer emits long beep > Insert time in seconds,
i.e. 10 > Green LED blinks > Buzzer emits long beep >
Changes done successfully

Note: The maximum delay time is 254s. If you want to insert values
less than 3-digits, hash (#) is required. E.g.: 10 will be keyed in as 10#.

ENABLE ALARM OUTPUT FROM DEVICE

It is optional to link s-Kadex to an alarm or siren to
amplify its alerts. Make sure you enable the alarm
output feature after linking up with the siren or alarm
system.

Operation: Verify your Admin password > Press 0 >
Green LED blinks > Buzzer emits long beep > Press 1 >
Green LED blinks > Buzzer emits long beep > Press 0 to
enable > Green LED blinks > Buzzer emits long beep >
Changes done successfully

s-Kadex

Stand-alone Card & Password

Access Control System

Back Plate

4 feet / 1.2 meter

(recommended)