Step 1
Determine the Location and Positioning
of the Installation
•
Avoid installing the terminals in locations that has contact with
a strong light source (e.g direct sunlight, spotlight, fluorescent
light, etc)
•
Avoid installing the terminals in locations with high moisture or
condensation levels in the air
•
The recommended installation height of the terminal from the
ground is 1.2 meter.
Step 2
Mounting of Terminals
A. Mount on WAll
•
After determining the height of the terminal from the ground
level and have made the relevant marks on the wall, based on
the measurements in Appendix II, drill the screws into the wall to
hang the terminals.
b. Flexi- Kit
FingerTec offers flexi-kit for all its time attendance models. Attach
the terminal on the flexi-kit for convenience.
Step 3
Wiring for Power Supply
The power jack is positioned on top of the terminal, labeled Power
Adapter Port in the below diagram.
Please use the power adaptor provided in the package or alterna-
tively you can opt for a linear power supply with specifications of
5VDC 2A. Plug one point of the power adapter to the terminal and
the other end to the power outlet. Don’t exceed the recommended
voltage or current to avoid damaging the terminal.
Step 4
Setting Up Data Communications
(Skip this step if you are using USB flash disk to transfer data)
TCP/IP – LAN Connection
For TCP/IP connection, plug the special RJ45 jack into the TCP/IP
(LAN) Port of the terminal. Connect the other end (normal RJ45 jack)
to the local area network hub or a PC. Configure the device ID, IP ad-
dress, subnet mask and Gateway in the terminal (refer to the hard-
ware user manual for details).