94 system functions – Leica Geosystems TPS1100 Professional Series - User Manual User Manual
Page 94

94
System functions
TPS1100 - User Manual 2.2.1en
6
0
2
21
26
Values can be entered directly with
the keyboard, or they can be
determined through the position of
the telescope.
Moves the telescope to the
position of the appropriate
limiting value. The value displayed
changes during the movement.
Accepts the value displayed
as being the limit of
movement.
\
Define Limits
Eyepiece V begin:
87°18'
Eyepiece V end :
114°18'
Lens V begin : 24°18'
Lens V end : 130°30'
Hz limit begin : 180°00'
Hz limit end : 180°00'
CONT
DEF
SET
MC
QUIT
If an accessory such as the eyepiece
prism or an additional lens for
measuring to retro foils is used, then
the movement for motorized
instruments is restricted by preset
values.
Sets the limits of the
movement
Returns all settings to NO.
Accessories
A starting value and a finishing value
are displayed. These determine the
limits of movement of the telescope
for motorized instruments. The range
of movement between the starting
value and the finishing value is
defined by one clockwise rotation.
The limits are entered for the vertical
angle for the objective side (lens)
and for the eyepiece side, and for the
horizontal directions. The altered
values are retained when the
instrument is switched off.
Main\ Accessories
Accessories are attached:
Eyepiece :
NO
Lens :
NO
Limit for horiz.rotation
Hz Limits active:
NO
CONT
DEF
DEFLT
MC
QUIT