Figure 11-29 – CANOGA PERKINS 9145E NID Software Version 4.10 User Manual
Page 245

Service OAM
9145E NID Software User’s Manual
Maintenance End Points
233
8. To change the Data TLV size, type 7 and press Enter. This value indicates the amount of
data in each packet. Type a value between 0 and 1491 and press Enter.
9. To change the Data TLV payload, type 8 and press Enter. Type the string that you want to
send in a loopback message and press Enter.
10. If you chose sweep mode in step 1, you can enter a start size and end size:
•
To enter a start size, type 5 and press Enter. Type a number from 30 to 1488 and
press Enter.
•
To enter an end size, type 6 and press Enter. Type a number from the range dis-
played on the screen and press Enter.
11. To send the loopback request, type S and press Enter.
12. Press Esc to return to the Maintenance End Point Attributes screen.
Figure 11-29 Unicast Loopback Monitoring screen
Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V04.10 05:15:27
-------------------------------LOOPBACK MONITORING-----------------------------
MEP ID: 100
Mode: Unicast regular
Destination: MEP ID : 200
P-Bit value: 7
DE bit value: 0
Transmission rate (pps): 10
Number of packets: 30 (0 - unfinished)
Data TLV size: 0 LBM size: 64 (31)
Data TLV payload: << randomly generated >>
Loopback Status: Active
First transaction ID: 1
Transmitted LBMs: 30
Received LBRs: 30
Select (S) to stop, (R) new request, (Ctrl+R) exit without aborting:
------------------------------------Messages-----------------------------------