4 oam event configuration – CANOGA PERKINS 9145E NID Software Version 4.10 User Manual
Page 191

Link OAM
9145E NID Software User’s Manual
OAM Event Configuration
179
9.4 OAM Event Configuration
To configure errors in the OAM, from the Link OAM screen, type 4 and press Enter. The OAM
Event Configuration screen (Figure 9-5) opens. Press Esc to return to the Link OAM screen.
Figure 9-5 OAM Event Configuration screen
Canoga Perkins Corp. Ethernet Network Interface Device 01-JAN-2009
9145E-101-1-0 V04.10 03:03:46
--------------------------------OAM EVENT CONFIGURATION------------------------
User Port Network Port
--------- ------------
1) Errored Symbol Period Window 125000000 125000000
2) Errored Symbol Period Threshold 1 1
3) Errored Frame Window (secs) 1.0 1.0
4) Errored Frame Threshold 1 1
5) Errored Frame Period Window 1488095 1488095
6) Errored Frame Period Threshold 1 1
7) Errored Frame Seconds Window (secs) 60.0 60.0
8) Errored Frame Seconds Threshold 1 1
9) Transmit Event Notification Count 1 1
10) Event Log Frequency (in 100 ms) 600 600
11) Send Errored Symbol Period Events Enabled Enabled
12) Send Errored Frame Events Enabled Enabled
13) Send Errored Frame Period Events Enabled Enabled
14) Send Errored Frame Seconds Events Enabled Enabled
15) Send Dying Gasp Events Enabled Enabled
16) Send Critical Events Enabled Enabled
Select [1-16]:
------------------------------------Messages-----------------------------------