CANOGA PERKINS 9145E NID Software Version 4.10 User Manual
Page 138

9145E NID Software User’s Manual
Diagnostics
Service Activation Testing
126
18. To create an L2CP profile, on the L2CP Profiles List screen (Figure 4-59), type A and
press Enter. The Create a New L2CP Profile screen (Figure 4-86) opens.
19. Follow the prompts to create an L2CP profile. When you are finished, type A to accept
and press Enter.
Figure 4-86 Create New L2CP Profile screen
20. To edit an existing L2CP Profile, on the L2CP Profiles List screen (Figure 4-59), type E
and press Enter. The first profile is selected.
21. Press the Space bar to select a profile and press Enter. The Modify L2CP Profile screen
opens (Figure 4-87).
22. To change the name of the profile, type 1 and press Enter. Type a new profile name and
press Enter.
23. Enter the number of the field you wish to edit and press Enter.
24. Press the Space bar to change the value (Drop or Pass).
25. When you are finished making changes, type A and press Enter.
26. Press Esc to return to the L2CP Profiles List.
Canoga Perkins Corp. Ethernet Network Interface Device 18-FEB-1970
9145E-761-0-0 V41.66 23:47:13
---------------------------- CREATE NEW L2CP PROFILE ---------------------------
ID : 12 Name: P-1
1) STP MSTP RSTP BPDU : Pass
2) Pause : Pass
3) LACP : Pass
4) Port Authentication : Pass
5) E-LMI : Pass
6) Provider Bridge : Pass
7) LLDP : Pass
8) MVRP : Pass
9) MMRP : Pass
10) CDP : Pass
11) VTP : Drop
12) PagP : Drop
13) PVST+ BPDU : Pass
14) Link OAM PDU : Pass
15) UDLD : Pass
16) Extreme Networks Discovery Protocol : Pass
Select [1-16]:
------------------------------------Messages----------------------------------