11.5.1 Display Maintenance Entity Groups
To display a list of existing Maintenance Entity Groups, on the SOAM Configuration screen
(Figure 11-7), type 4 and press Enter. The Maintenance Entity Group List screen (Figure 11-17)
opens.
Figure 11-17 Maintenance Entity Group List screen
11.5.2 Create a Maintenance Entity Group
1. On the Maintenance Entity Group List screen (Figure 11-17), type A and press Enter. The
Create a New Maintenance Entity Group screen (Figure 11-18) opens. The first field,
MEG ID, is highlighted.
2. Type a MEG ID and press Enter. The Level field is highlighted.
3. In the Level field, type a number between 0 and 7. Higher numbers correspond to higher
Maintenance Domains, that is, those with the greatest physical reach, with the highest
values for customers' CFM packets. Lower numbers correspond to lower Maintenance
Domains, those with more limited physical reach, with the lowest values for CFM PDUs
protecting single bridges or physical links. Press Enter. The Name field is highlighted.
4. Select a Name Format (ICC-based or Character string) and press Enter. (ICC is the
Name Format specific to the Y.1731 standard.) The Name field is highlighted.
5. Type a Name for the Maintenance Entity group and press Enter. The VLAN Tag Type
field is highlighted.
6. Select a VLAN Tag Type (C-Tag, S-Tag, or None).
•
C-Tag indicates that ethernet frames (CCMs, LBMs, LBRs, LTMs, LTRs) are
tagged with a VLAN tag for the customer space. If All-to-One Bundling is enabled,
C-Tagged frames may be sent double tagged, according to the rules described in
the section “SOAM Functionality with All-to-One Bundling” on page 199.
Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V04.10 05:15:27
------------------------MAINTENANCE ENTITY GROUP LIST--------Display 1 - 2 of 2-
MEG ID LEVEL NAME VLAN LIST
100 6 meg100 N/A
101 7 ag-comp-101 900
Select [(F)irst, (P)rev, (N)ext, (L)ast] to change pages,
(A)dd new, (D)elete, (E)dit, ESC to return: