CANOGA PERKINS 9145E NID Software Version 4.10 User Manual
Page 234

9145E NID Software User’s Manual
Service OAM
Maintenance Entity Groups
222
•
To remove a peer MEP, type 2 and press Enter. You are prompted for the MEP ID
number. Type the number and press Enter.
•
When all the peer MEPs have been configured, type A to accept and press Enter.
•
Press Esc to return to the Maintenance Entity Group Attributes screen
8. You can change the Permissions (Sender ID). Select None, Chassis, Manage,
ChassisManage, or Defer, and press Enter.
9. When you are finished, type A to accept the settings and press Enter.
10. Press Esc to return to the Maintenance Entity Group List screen.
Figure 11-19 Maintenance Entity Group Attributes screen
Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V04.10 05:15:27
---------------------MAINTENANCE ENTITY GROUP ATTRIBUTES-----------------------
MEG ID:100 Name: meg100
Name Format: ICC-based Format
Level: 6
1) CCM Interval: 1 sec
VLAN Tag Type: C-Tag
VLAN List: 100
2) Add VLAN to VLAN List.
3) Remove VLAN from VLAN List.
4) View/Modify Peer MEPs list.
5) Permissions (Sender ID): None
Select [1-5] for attributes:
------------------------------------Messages-----------------------------------