beautypg.com

2 configuration overview, Configuration overview – Pilz PNOZ s50 C User Manual

Page 59

background image

Examples

Operating Manual PNOZ s50
1002194­EN­02

59

Safety control system

}

Inputs:

Fault signal O3

State of brakes O4, O5 (applied, ventilated) is monitored

}

Outputs

Activation of fast and slow shutdown of brake

Brake

}

Micro switch S1 to signal the state of brake B1

}

Micro switch S2 to signal the state of brake B2

8.2.2

Configuration overview

The following parameters must be set in the display menu:

Function

Terminal Description

Parameter

Value

In display menu

Supply voltage,
power circuits 1
and 2

B1/B2

Supply voltage

Input Voltage

24 V

Input ­> Input Voltage

Test pulse

Y1/Y2

Test pulses on feed­
back loops

Pulsing

On

Feedback ­> Pulsing
­>

Y1/Y2 Pulse

Power circuit 1

O1+/O1­

Reduced voltage

U

12 V

Output ­> O1

Overexcitation time

T

450 ms

Output ­> O1

Y1

Maximum ventilation
time

Ton

60 ms

Feedback ­> Y1 ­>

Y1 Timing ­> Y1 Ton

Maximum application
time, fast shutdown

Toff fast

30 ms

Feedback ­> Y1 ­>

Y1 Timing ­> Y1 Toff

Maximum application
time, slow shutdown

Toff slow

150 ms

Feedback ­> Y1 ­>

Y1 Timing ­> Y1 Toff

Logic of feedback loop
1

Logic

N/C

Feedback ­> Y1 ­>

Logic ­> Y1 Logic

Power circuit 2

O2+/O2­

Reduced voltage

U

12 V

Output ­> O2

Overexcitation time

T

450 ms

Output ­> O2

Y2

Maximum ventilation
time

Ton

60 ms

Feedback ­> Y2 ­>

Y1 Timing ­> Y2 Ton

Maximum application
time, fast shutdown

Toff fast

30 ms

Feedback ­> Y2 ­>

Y1 Timing ­> Y2 Toff

Maximum application
time, slow shutdown

Toff slow

150 ms

Feedback ­> Y2 ­>

Y1 Timing ­> Y2 Toff

Logic of feedback loop
2

Logic

NC

Feedback ­> Y2 ­>

Logic ­> Y2 Logic