6 commissioning, 1 wiring, 1 general wiring guidelines – Pilz PNOZ s50 C User Manual
Page 26: 2 pin assignment, Section 6, Commissioning, Wiring, General wiring guidelines, Pin assignment, 6commissioning

Commissioning
Operating Manual PNOZ s50
1002194EN02
26
6
Commissioning
6.1
Wiring
6.1.1
General wiring guidelines
Note:
}
Information given in the "Technical details" must be followed.
}
Use copper wire that can withstand 75 °C.
}
The wiring must be designed to achieve sufficient noise immunity and protection
against noise emissions in terms of EMC. Please also refer to DIN EN 602041 (Elec
trical equipment of machines).
Inputs
}
Appropriate wiring must be used to exclude short circuits between the inputs or to a
supply line!
Outputs
}
If short circuits occur between the cable from the output to the load and a supply line, it
will no longer be possible to switch off the load.
Possible remedy: Exclude the error by using separate multicore cable for supply
voltages
}
Use appropriate wiring to exclude short circuits between the outputs!
6.1.2
Pin assignment
Female connector X1
Terminal
Description
A2 A2 S36 S35 S11 S11 T1 T0
x
1
A2
Reference potential for
Device's supply voltage
Inputs
Fault signal and status outputs
S36
Standard input for slow shutdown, power
circuit 2
S35
Standard input for slow shutdown, power
circuit 1
S11
Voltage output 24 VDC
S11
Voltage output 24 VDC
T1
Test pulse output 1
T0
Test pulse output 0